add new ticker to check after 500ms if water outage is correct.

This commit is contained in:
lukas 2021-04-03 17:16:24 +02:00
parent 6adfb3c09e
commit 697ed69d95
2 changed files with 41 additions and 34 deletions

View File

@ -16,6 +16,6 @@
#define TempSensorPin D4 #define TempSensorPin D4
// version info // version info
#define VERSION "v1.2.4-Alpa1" #define VERSION "v1.2.4-Alpha2"
#endif //PUMPENSTEUERUNG_PINS_H #endif //PUMPENSTEUERUNG_PINS_H

View File

@ -15,7 +15,7 @@ bool error = false;
Ticker status; Ticker status;
//pumpendauer maximum ticker //pumpendauer maximum ticker
Ticker pumpendauer; Ticker pumpendauer, wasserSensorDoubleCheck;
//WifiManager mang; //WifiManager mang;
Heating mHeat; Heating mHeat;
@ -45,9 +45,10 @@ void pumpeSchalten(bool on) {
pumpcycles++; pumpcycles++;
generalinfo.setPumpCycles(pumpcycles); generalinfo.setPumpCycles(pumpcycles);
pumpendauer.once((float)settingsservice.getSettings()->maxpumpduration + 1, []() { pumpendauer.once((float) settingsservice.getSettings()->maxpumpduration + 1, []() {
//erlaube keine einschaltung von mehr als 60 sek //erlaube keine einschaltung von mehr als 60 sek
if (Timer::getSystemSeconds() - turnontime >= (unsigned)settingsservice.getSettings()->maxpumpduration && turnontime != 0) { if (Timer::getSystemSeconds() - turnontime >=
(unsigned) settingsservice.getSettings()->maxpumpduration && turnontime != 0) {
//error zu lange //error zu lange
Serial.println("\n\npumpe lief mehr als 10 Minuten durchgaengig"); Serial.println("\n\npumpe lief mehr als 10 Minuten durchgaengig");
pumpeSchalten(false); pumpeSchalten(false);
@ -64,7 +65,8 @@ void pumpeSchalten(bool on) {
digitalWrite(SchuetzPin, on); digitalWrite(SchuetzPin, on);
Serial.println("[Erfolg] pumpe wird geschalten"); Serial.println("[Erfolg] pumpe wird geschalten");
} else { } else {
Serial.println("[FEHLGESCHLAGEN] Schalten des Schütz gesperrt durch Timeout oder Fehler-- sofortiges ausschalten der pumpe\n"); Serial.println(
"[FEHLGESCHLAGEN] Schalten des Schütz gesperrt durch Timeout oder Fehler-- sofortiges ausschalten der pumpe\n");
turnontime = -1; turnontime = -1;
digitalWrite(SchuetzPin, LOW); digitalWrite(SchuetzPin, LOW);
} }
@ -93,41 +95,46 @@ int wateroutagewaitduration;
void WasserSensorCheck() { void WasserSensorCheck() {
if (digitalRead(WasserSensorPin) == LOW) { if (digitalRead(WasserSensorPin) == LOW) {
Serial.println("Wasser Sensor AUS"); // check if water sensor is also low after 500ms and lock it then
//kein Wasser dh timer auf 10min stellen wasserSensorDoubleCheck.once_ms(500, []() {
if (digitalRead(WasserSensorPin) == LOW) {
Serial.println("Wasser Sensor AUS");
//kein Wasser dh timer auf 10min stellen
// refresh wateroutage counter // refresh wateroutage counter
generalinfo.setlastWaterOutage(Timer::getSystemSeconds()); generalinfo.setlastWaterOutage(Timer::getSystemSeconds());
allow = false; allow = false;
Serial.println("Schalte pumpe aus"); Serial.println("Schalte pumpe aus");
pumpeSchalten(false); pumpeSchalten(false);
Serial.println("warte 30min"); Serial.println("warte 30min");
status.detach();
wateroutagewaitduration = settingsservice.getSettings()->waterOutageWaitDuration;
status.detach();
status.attach(5, []() {
wateroutagewaitduration -= 5;
Serial.print("noch ");
Serial.print(wateroutagewaitduration);
Serial.println(" Sekunden verbleibend");
if (wateroutagewaitduration <= 0) {
status.detach(); status.detach();
if (digitalRead(WasserSensorPin)) {
allow = true;
Serial.println("Einschalten der Pumpe wieder erlaubt.");
//pruefen ob drucksensor ein wateroutagewaitduration = settingsservice.getSettings()->waterOutageWaitDuration;
DruckschalterInt();
} else { status.detach();
Serial.print("wassersensor immer noch kein Wasser --> verlaengern um 120min\n\n"); status.attach(5, []() {
WasserSensorCheck(); wateroutagewaitduration -= 5;
} Serial.print("noch ");
Serial.print(wateroutagewaitduration);
Serial.println(" Sekunden verbleibend");
if (wateroutagewaitduration <= 0) {
status.detach();
if (digitalRead(WasserSensorPin)) {
allow = true;
Serial.println("Einschalten der Pumpe wieder erlaubt.");
//pruefen ob drucksensor ein
DruckschalterInt();
} else {
Serial.print("wassersensor immer noch kein Wasser --> verlaengern um 120min\n\n");
WasserSensorCheck();
}
}
});
} }
}); });
} else { } else {