interrupt full heat cycle when pump starts
This commit is contained in:
parent
39a8ecde85
commit
3a5f1a3a74
@ -62,7 +62,10 @@ void Heating::init(unsigned mode, const SettingState *settings, HeatingInfoServi
|
||||
});
|
||||
|
||||
mHeizungTicker.attach(10, [this]() {
|
||||
sensor.read();
|
||||
// only check if no pump cycle is active
|
||||
if (!mPumpCycleActive) {
|
||||
sensor.read();
|
||||
}
|
||||
});
|
||||
|
||||
break;
|
||||
@ -78,10 +81,8 @@ void Heating::handleHeatingEvents() {
|
||||
// turn off active turnoff timers
|
||||
mLuefterTicker.detach();
|
||||
//Serial.println("heating should run now!");
|
||||
// turn on heating and fan
|
||||
if (!mPumpCycleActive) {
|
||||
digitalWrite(LuefterPin, HIGH);
|
||||
}
|
||||
|
||||
digitalWrite(LuefterPin, HIGH);
|
||||
|
||||
digitalWrite(HeizungPin, HIGH);
|
||||
|
||||
@ -150,9 +151,21 @@ void Heating::setPumCycleActive(bool active) {
|
||||
// turn off fan if pumpcycleactive
|
||||
if (active) {
|
||||
digitalWrite(LuefterPin, LOW);
|
||||
} else {
|
||||
digitalWrite(HeizungPin, LOW);
|
||||
|
||||
mHeizungTicker.detach();
|
||||
|
||||
if (mHeatingStatus) {
|
||||
digitalWrite(LuefterPin, HIGH);
|
||||
// to add the correct time to the heat min counter!
|
||||
mheatingservice->addHeatTime(Timer::getSystemSeconds() - mheatingservice->getLastHeatingStartTime());
|
||||
}
|
||||
} else {
|
||||
mHeizungTicker.detach();
|
||||
mHeizungTicker.attach(10, [this]() {
|
||||
// only check if no pump cycle is active
|
||||
if (!mPumpCycleActive) {
|
||||
sensor.read();
|
||||
}
|
||||
});
|
||||
}
|
||||
}
|
||||
|
Loading…
Reference in New Issue